DOUBLE STAKED DRYER

DOUBLE STAKED DRYER


Double stacked dryers are produced by the second module installation over the base module. The base module has two fans and two burners with a dividing of the plenum in the proportion 2/3 and 1/3. The modules hitch up with the help of the special side posts.

sukup_2stacked_3fans.jpgsukup_2stacked_4fans.jpg


















The upper module  of such dryers may have one or two fans with the burners. regardless of the number of the fans, the chamber of the upper module doesn't have a baffle. 

When the dryer runs in Heat/Cool mode the grain gets hot in the upper module and in the upper chamber of the lower module., and gets cool in the lower chamber of the lower module. The lower burner of the lower module is not switched on; only the fan is in operation.

If the dryer runs only in Heat mode, the lower chamber of the lower module is also used for heating.

Efficiency  of double stacked dryers are the same for the dryers with three fans, if the upper module has one fan, and for the dryers with four fans, if he upper module has two fans.

Regardless of the number of the fans and the burners in the upper module, the volume and the  temperature of the heated air which get through the grain will be the same.

Technical features of a double stack dryer

Model TE1652E TE2052E TE2062E TE2452E TE2462E
The grain moisture reducing from 30% up to 15% (only heating, without grain cooling in the dryer)*, t/h 14,9 18,5 18,5 22,7 22,7
The grain moisture reducing from 25% up to 15% (only heating, without grain cooling in the dryer)*, t/h 25,4 31,7 31,7 38,7 38,7
The grain moisture reducing from 20% up to 15% (only heating, without grain cooling in the dryer)*, t/h 40,6 61,3 51,3 62,2 62,2
The grain moisture reducing from 30% up to 15% (heating and cooling), t/h 10,6 13,3 13,3 15,9 15,9
The grain moisture reducing from 25% up to 15% (heating and cooling), t/h 17,3 21,9 21,9 26,2 26,2
The grain moisture reducing from 20% up to 15% (heating and cooling), t/h 27,4 35,0 35,0 42,4 42,4
Technical features
Capacity (corn), t 21,59 26,67 26,67 31,75 31,75
Size of the grain column (width х length), m

0,36 х

4,88

0,36 х

6,1

0,36 х

6,1

0,36 х

7,32

0,36 х

7,32

Gas flow rate (max), m3/h 361 458 458 555 555
Gas flow rate (med), m3/h 180-241 229-305 229-305 278-370 278-370
Propane-butane flow rate (max) l/h 442 561 561 680 680
Propane-butane flow rate (med) l/h 221-295 281-374 281-374 340-453 340-453
The power of fan motor (upper/lower),kW

(1) 11,19

(2) 7,46

(1) 22,37

(2) 11,19

(2) 11,19

(2) 11,19

(1) 29,83

(2) 14,91

(2) 14,91

(2) 14,91

Fan diameter (upper/lower), m

(1) 1,12

(2) 0,97

(1) 1,12

(2) 0,97

(2) 0,97

(2) 0,97

(1) 1,12

(2) 0,97

(2) 0,97

(2) 0,97

The power of loading auger motor,kW 2,24 3,73 3,73 3,73 3,73
The power of unloading auger motor, kW 2,24 3,73 3,73 3,73 3,73
The capacity of loading/unloading auger, t/h 60,96 76,2 76,2 91,44 91,44
Transportation height (all modules), m 4,06 4,06 4,06 4,06 4,06
Height (fron the base, with the bin for wet grain and 3 legs), m 8,92 8,92 8,92 8,92 8,92
Length (without drawbar hitch), m 7,62 8,84 8,84 10,06 10,06
Length (with drawbar hitch), m 8,08 9,3 9,3 10,52 10,52
Width (without wheels), m 2,54 2,54 2,54 2,54 2,54
Width (with wheels), m 2,67 2,67 2,67 2,67 2,67
Weight (with wheels and the bin for wet grain), kg 10 886 12 246 12 246 13 607 13 607
Voltage

3 phases,

380 V

3 phases,

380 V

3 phases,

380 V

3 phases,

380 V

3 phases,

380 V